Skip to main content

Trở xả

Bảng Trở xả GD200A

Công suất (kW)Braking unitResistor at 100% (Ω)CS R hãm 10% (kW)CS R hãm 50% (kW)CS R hãm 80% (kW)Điện trở hãm min (Ω)
0.75Tích hợp sẵn6530.10.60.9240
1.5Tích hợp sẵn3260.231.11.8170
2.2Tích hợp sẵn2220.331.72.6130
4Tích hợp sẵn1220.634.880
5.5Tích hợp sẵn890.754.16.660
7.5Tích hợp sẵn651.15.6947
11Tích hợp sẵn441.78.313.231
15Tích hợp sẵn322111823
18.5Tích hợp sẵn273142219
22Tích hợp sẵn223172617
30Tích hợp sẵn175233617
37DBU100H-060-4136284411.7
45DBU100H-110-4107345411.7
55DBU100H-110-48841666.4
75DBU100H-110-46.51156906.4
90DBU100H-160-45.414681084.4
110DBU100H-160-44.517831324.4
132DBU100H-220-43.720991583.2
160DBU100H-320-43.1241201922.2
185DBU100H-320-42.8281392222.2
200DBU100H-320-42.5301502402.2
220DBU100H-400-42.2331652641.8
250DBU100H-400-42.0381883001.8
2802 × DBU100H-320-43.6 × 221 × 2105 × 2168 × 22.2 × 2
3152 × DBU100H-320-43.2 × 224 × 2118 × 2189 × 22.2 × 2
3552 × DBU100H-320-42.8 × 227 × 2132 × 2210 × 22.2 × 2
4002 × DBU100H-320-42.4 × 230 × 2150 × 2240 × 22.2 × 2
4502 × DBU100H-400-42.2 × 234 × 2168 × 2270 × 21.8 × 2
5002 × DBU100H-400-42.0 × 238 × 2186 × 2300 × 21.8 × 2

Lưu ý:

  • Các model từ 0.75 kW đến 30 kW tích hợp sẵn bộ hãm (Built-in Braking Unit).
  • Các model từ 37 kW trở lên cần sử dụng bộ hãm ngoài (DBU).
  • Điện trở thực tế sử dụng không được nhỏ hơn giá trị trong cột Điện trở hãm tối thiểu cho phép, nếu không có thể gây quá dòng hoặc hỏng bộ hãm.
  • Với các model từ 280 kW trở lên, cần sử dụng 2 bộ hãm hoạt động song song.

Cách đấu